Skip to main content

Cardioplegia at subnormothermia facilitates rapid functional resuscitation of hearts preserved in SOMAH for transplants

Abstract

Objectives

Hearts preserved ex vivo at 4°C undergo time-dependent irreversible injury due to extreme hypothermia. Studies using novel organ preservative solution SOMAH, suggest that hearts are optimally `preserved' at subnormothermic temperature of 21°C. Present study evaluates relative efficacy of SOMAH `cardioplegia' at 4 and 21°C in preservation of optimum heart function after in vitro storage at subnormothermia.

Methods

Porcine hearts arrested with SOMAH cardioplegia at 4 or 21°C were stored in SOMAH for 5-hour at 21°C (n = 5). At the end of storage, the weight of hearts was recorded and biopsies taken for cardiac tissue high energy phosphate level measurements. The hearts were then attached to a reperfusion apparatus and biochemical parameters including cardiac enzyme release and myocardial oxygen consumption and lactate production were determined in perfusate samples at regular intervals during ex vivo perfusion experiment. Functional evaluation of the hearts intraoperatively and ex vivo was performed by 2D echocardiography using trans-esophageal echocardiography probe.

Results

Post-storage heart weights were unaltered in both groups, while available high-energy phosphates (HEP) were greater in the 21°C group. Upon ex vivo reperfusion, coronary flow was significantly greater (p < 0.05) in 21°C group. 2D echo revealed a greater cardiac output, fractional area change and ejection fraction in 21°C group that was not significantly different than the 4°C group. However, unlike 4°C hearts, 21°C hearts did not require inotropic intervention. Upon reperfusion, rate of cardiac enzyme release temporally resolved in 21°C group, but not in the 4°C group. 21°C working hearts maintained their energy state during the experimental duration but not the 4°C group; albeit, both groups demonstrated robust metabolism and function during this period.

Conclusions

Rapid metabolic switch, increased synthesis of HEP, decreased injury and optimal function provides evidence that hearts arrested at 21°C remain viably and functionally superior to those arrested at 4°C when stored in SOMAH at ambient temperature pre-transplant.

Ultramini-abstract

Cardioplegic arrest and preservation of hearts in SOMAH at ambient temperature efficiently conserves metabolism and function in in vitro porcine model of heart transplant.

Peer Review reports

Background

Cardioplegia, a technique to stop the heart intraoperatively, is an integral part of open-heart surgeries and is also a fundamental requisite in the field of heart transplant. During surgery it is important for cardioplegia solution to not only arrest the heart adequately but also prevent damage to cardiac tissue during and/or after infusion. Several strategies to attain this ideal situation have been attempted by altering cardioplegia temperature, or using blood, crystalloid or blood-crystalloid mixture that have produced equivocal results in their ability to arrest the heart [1]-[6]. However, the meta-analysis of these studies does not provide much evidence in favor of one or the other [7],[8]. Nevertheless, of all these strategies by far, the use of high K+ cardioplegia at extreme hypothermia (4°C) has become most widely accepted, especially in the procurement of donor hearts for transplant [9]. This is despite the growing awareness of the damaging effects of extreme hypothermia on solid organs [10],[11] and failure of presently used modalities in extracorporeal preservation of hearts to extend the ex vivo storage time beyond 4-6 hours.

Recent results from our laboratory using animal models of heart transplant have demonstrated that hearts preserved in SOMAH solution of our design, demonstrate greater accumulation of high energy phosphates (HEP) in comparison to the comparator solutions [12]-[16]. Furthermore, hearts preserved in SOMAH for 5-24 hours and not exposed to extreme hypothermia (4°C) demonstrate a robust maintenance of organ viability and function, and minimal injury upon reperfusion and reanimation [12]-[14]. Additionally, these studies also demonstrate that hearts stored in SOMAH at 21°C outperform those preserved at 4 and 13°C upon reanimation. However, in these investigations SOMAH cardioplegia was delivered at 4°C for arrest prior to excision of donor hearts. Since preservation of hearts in SOMAH at 21°C was superior than that at 4°C, the present study was undertaken to assess whether delivery of high K+ SOMAH cardioplegia at 21°C compared to that at 4°C would further augment and improve viability and energy metabolism, and also prevent injury in hearts stored ex vivo for 5 hours at 21°C, that were then reperfused and reanimated for evaluation of cardiac function.

Methods

Animal protocol

Heart procurement surgery and cardioplegia

Ten female Yorkshire swine (45-54 Kg) were used in this comparative study. Hearts were divided into two groups of either 4°C (n = 5) or 21°C cardioplegia (n = 5), as per the protocol approved by our Animal Studies Committee (Institutional Animal Care and Use Committee). Hearts were extracted using mediastinal approach as described [12]. The animals were bled from femoral vessels to collect blood for ex vivo experiments, and aorta was clamped when systolic pressure fell below 40 mmHg. 1000 ml of SOMAH cardioplegia (SOMAH [12] modified by addition of 20 mM K+, final concentration), at 4 or 21°C was infused into the aortic root at a pressure of 75-100 mmHg at a flow rate of 300-400 ml/minute using roller pump and pressure transducer (Myotherm Cardioplegia System, Medtronics, Minneapolis, MN, USA) and the data was recorded using iWorks system (Dover, NH, USA). After cardioplegic arrest, heart was dissected from all attachments and rinsed with normal saline before storing in SOMAH for 5-hours at 21°C. Hearts were transported to the lab within 15 minutes of excision.

Extracorporeal storage of heart

Hearts were placed in sterile zip-lock bags containing 2 L of SOMAH in water-jacketed water bath at 21 ± 2°C. The temperature of preservation solution was checked regularly during the entire storage period. Hearts were maintained in a non-contractile state by increasing SOMAH's plegia potential by supplementing the solution with 20 mM K+ complemented by 37 mM Mg2+[17],[18], during storage. Hearts in each group were weighed prior to and after 5-hour storage upon carefully emptying the heart chambers. Tissue punch biopsies (2X4 mm) were taken in the lab from the posterior wall of LV, 15 minutes into (0 hour; control) and after 5 hour storage for HEP assays.

ATP and creatine phosphate assay

ATP and creatine phosphate (CP) were measured in tissue extracts as described [12],[19]. In brief, tissue biopsies were flash frozen and stored at -80°C; 20 mg of tissue was suspended in 400 μl of 0.4 M ice-cold perchloric acid and homogenized twice for 30 seconds. Homogenate was centrifuged at 1970 g for 10 minutes at 0°C. An aliquot of supernatant was neutralized with equal volume of ice-cold 0.4 M KHCO3 and centrifuged as above. The supernatant was stored at -80°C for ATP and CP measurements. The pellet was dissolved in equal volume of 0.1 M NaOH, centrifuged and used for protein assay. ATP and CP were measured using a bioluminescent assay kit (Sigma-Aldrich and GloMax-Multi + Detection System, Promega), according to the protocol provided by the manufacturer.

Preparation of heart for ex vivo resuscitation and functional studies

Aorta and pulmonary artery (PA) were separated. Aorta was cannulated (1/2-3/8 inch tubing connector) and coronaries were gently flushed with 100 ml of SOMAH in both 4°C and 21°C cardioplegia groups at 40-50 mmHg pressure, carefully avoiding entry of air into the aorta. Pulmonary veins (PV) were separated and cannulated with 1/2-1/4 inch tubing connector. PA was cannulated for sample collection while superior and inferior vena cavas were ligated.

Preparation of blood for ex vivo studies

Systemically heparinized blood was collected intraoperatively, leukodepleted (Pall Leukoguard filter) and stored at 4°C. Prior to experiments, perfusate was prepared by adjusting the hematocrit of blood to 20% using SOMAH solution (1:1 ratio to reduce viscous strain on heart) and warmed to 21°C. The perfusate, pH, glucose, K+, Ca2+ and HCO3- were adjusted for swine blood levels (7.5; 100 mg/dl; 3.7, 1.38, and 32 mmol/l respectively), using 10% dextrose, KCl, CaCl2 and NaHCO3, respectively, as required.

The SOMAH device

A custom-built apparatus was used for extra-corporeal reanimation of hearts (Figure 1, Additional file 1: Video). CDI monitor (Clinical Documentation Improvement monitoring system 500, Terumo cardiovascular systems corporation, Ann Arbor, MI), was used for real-time monitoring of perfusate pH, temperature, pO2, pCO2, K+ and HCO3 -. These parameters were also analyzed in inflow/outflow samples using i-STAT analyzer (Abaxis Ltd, Union city, CA). Pressures and flows were recorded at various points in the circuits (Figure 2). A trans-esophageal echocardiography (TEE) probe was used to assess the contractile function of heart using the 2D-Echo system. 3-lead ECG was recorded during 2D Echo using brass crocodile leads immersed in the perfusate surrounding the heart. Pressures and flow data was acquired and monitored in real time using HMI software, specifically written for SOMAH Device (Comdel Inc, Wahpeton, ND).

Figure 1
figure 1

Circuit diagram of the SOMAH Device. A custom-built apparatus was designed for extra-corporeal reanimation of hearts. The circuit 1 (green) visualizes antegrade coronary perfusion through aorta during initial reperfusion of hearts and circuit 2 (red), for perfusion of hearts through PV in the working state. In circuit 1, the perfusate is pumped from heart chamber to oxygenator-heat-exchanger system and eventually into aorta for coronary perfusion. The return of perfusate to heart chamber through PA completes the circuit. In circuit 2, blood pumped from heart to oxygenator-heat-exchanger system is collected in pre-load bag from where it drained into the PV by gravity. The pressures/flows are adjusted by altering the height of pre-load bag. This circuit is diverted into two components. First component is the part of perfusate that enters coronaries and returns to heart chamber through PA. The second component is formed by the perfusate that continues through aorta into the after-load chamber, from where the perfusate returns to heart chamber by gravity. A CDI monitor was incorporated beyond oxygenator-heat-exchanger system for real-time monitoring of perfusate pH, temperature, pO2, pCO2, K+ and HCO3-. Pressures and flows were recorded at various points in the two circuits and monitored using HMI software specifically written for SOMAH Device.

Figure 2
figure 2

Flow diagram of experimental design. Illustration shows the general experimental design of this study, starting from intraoperative cardioplegia for cardiac arrest to the end of ex vivo heart reperfusion experiment.

Ex vivo functional studies

Hearts were attached to SOMAH Device and perfused through the aorta at 40-60 mmHg for 5 minutes, with 1-1.5 liters of SOMAH at 21°C (pH 7.5), and then with perfusate, till pH, blood gases and electrolyte equilibrium was established. The perfusate pH, glucose, K+, Ca2+, HCO3- were adjusted for swine blood levels as mentioned above. Strong cardiac contractions were noted in both groups as the system temperature was gradually raised to 37°C over a 30 minute period. Hemodynamic steady state (with respect to pH, blood gases, and electrolytes) was achieved within 40 minutes. Total duration of the experimental perfusion was approximately 180 minutes. Hearts were perfused through aortic root (no workload) until the system temperature reached 37°C, after which PV perfusion (full workload) proceeded until end of experiment. Coronary blood flow was determined during the initial antegrade perfusion by the amount of perfusate flowing to the heart through aorta per minute, and in the working heart by the amount of perfusate collected from pulmonary artery (both cavas ligated) per minute. Electroconversion (40-50 J) and/or epinephrine (1:50,000-1:100,000) were used if required [14]-[16]. Epicardial 2D Echo was performed using TEE probe for functional assessment at 60 minutes (baseline) and at peak performance, approximately 90 minutes after initiation of perfusate perfusion in the two groups with hearts under full workload; and every 30 minutes thereafter. Peak cardiac performance was defined by the maximum contractile activity observed by 2D Echo. The data at peak performance was used for comparisons between the two groups.

Enzyme assays and blood chemistry

Quantitative levels of cardiac creatine kinase (CK), aspartate aminotransferase (AST), troponin-I (cTnI), lactate and gases (pO2/pCO2) were measured intra-operatively and in SOMAH samples taken at 10 minute, 2-hour and at end of 5-hour heart storage using Vetscan VS2 or iStat (Abaxis Ltd, Union City, CA). Inflow (aortic) and outflow (PA) samples were collected for enzyme assays and post perfusion assessment of myocardial O2 consumption (MVO2) and lactate levels using Vetscan VS2 or i-Stat System, at 5 and 90 minutes for enzyme assays, and at 60 minutes (baseline) and 90 minutes (peak performance) for MVO2 and lactate, after start of perfusate perfusion with Vetscan or iStat. MVO2 was calculated as described [20].

Epicardial echocardiography

A trans-esophageal (TEE) probe was used for 2D echo evaluation of cardiac function intra-operatively and ex vivo using the Acuson Cypress system (Acuson, Mountain View, CA) and images were analyzed using Cypress viewer software provided with the system. Hearts were connected to SOMAH Device and suspended in a chamber containing 2 L of perfusate that covered 2/3rd surface of the heart. ECG was recorded during entire course of the experiment and 2D Echo acquisition was begun approximately 45-60 minute after perfusion, when good cardiac contractions were observed, and repeated at 30-minute intervals. Probe was placed in direct contact with heart and angle of probe and direction of pulse were adjusted as to obtain short-axis and long-axis views for calculations of cardiac functional parameters, and ventricular wall and septal thickness.

Statistical analyses

Equal number of animals (n = 5), were assigned to 4°C and 21°C cardioplegia groups for comparative analysis for biochemical, hemodynamic and functional measurements from each group. Statistical comparison for significant differences between the two groups was performed using SigmaPlot software. Paired t-test was used for all comparisons. P-value of <0.05 was considered significant. All values are expressed as mean ± SEM. Flow diagram of the experimental design is shown in Figure 2.

The authors had full access to the data and take full responsibility for its integrity. All authors have read and agreed to the manuscript as written. The funding agencies did not play any role in influencing data collection, extraction and interpretation.

Results

Intraoperative cardioplegia

Cardiac arrest was dependent on the temperature of cardioplegia and occurred within 10-15 seconds in 4°C group and 20-25 seconds in the 21°C group, likely because the hypothermic (4°C) component of cardiac arrest was deliberately eliminated in the latter.

Gross morphology, heart weights and release of enzymes during storage

Irrespective of temperature of cardioplegia, all hearts presented normal gross morphology without any discoloration. Hearts were pliable with no signs of hardening or stiffness. Weights of the hearts during 5-hour storage in the two groups were not altered between pre and post storage, demonstrating lack of storage-induced gross edema (not shown). A time dependent release of cardiac enzymes was minimally apparent in both groups that were not significantly different (not shown).

Cardiac tissue HEP levels after arrest and during storage

As shown in Figure 3, concentration of ATP, CP and total high-energy phosphates (HEP), within 15 minutes (control) of cardiac arrest were significantly greater in 4°C as compared to 21°C cardioplegia hearts (P < 0.001) possibly due to the greater consumption of energy in 21°C group hearts as they required approximately 10 seconds longer for total arrest. Both groups actively synthesized CP and ATP during storage, Figure 3B. While the total concentrations of HEP at the end of storage were significantly greater in 4°C hearts (P < 0.01), normalization of values at 5 hour with respect to those at 0 hour demonstrated greater availability of HEP in 21°C hearts than in 4°C hearts at the end of storage, Figure 3C.

Figure 3
figure 3

High energy phosphate levels in hearts arrested and stored in SOMAH. Cardiac tissue biopsies from left ventricle were obtained for determination of HEP including ATP and CP levels in 4 and 21°C SOMAH cardioplegia group hearts pre and post 5-hour storage. There was a temperature of cardioplegia arrest dependent increase in HEP concentrations in the hearts. A: Control; B: 5 hour storage; C: Normalized values (5 hours with respect to 0 hour). Each bar represents mean ± SEM of n = 5 for each group. * Significantly different from 4°C cardioplegia group hearts.

Ex vivo cardiac functional studies

Coronary flow upon reperfusion

Coronary flow through the aorta, upon initial antegrade perfusion at similar perfusion pressures, was significantly greater in 21°C hearts (P < 0.05) than the 4°C group (Table 1). The hearts in both groups demonstrated slow four chamber contractions immediately upon initiation of perfusion. Coronary flow decreased initially when system temperature was raised to 30°C, as the hearts started contracting vigorously. Both pressure and flow increased as system temperature was raised to 37°C. Coronary flow was highest in both groups at 37°C (Table 1).

Table 1 Coronary flow (ml/min) in differential temperature cardioplegia hearts with the rise in system temperature of SOMAH Device

Release of enzymes upon reperfusion

Rate of CK, AST and cTnI release increased in 4°C hearts during the perfusion period (Figure 4). Both CK and cTnI release increased significantly with the time of perfusion, but the AST did not. In contrast, there was a temporal decrease in release of these three enzymes in the 21°C hearts during the same period (Figure 4). However, release of CK and cTnI, but not the AST, was significantly greater by the 21°C hearts upon initiation of perfusion than by the 4°C hearts.

Figure 4
figure 4

Release of creatine kinase and cardiac troponin-I upon reperfusion. CK (A), AST (B) and cTnI (C) levels were determined in perfusate, 5 min and 90 min (peak performance) after start of reperfusion of 4 and 21°C cardioplegia hearts; n = 5 for each SOMAH group. *Significant change from 5 minutes (p <0.05); * Significantly different from 4°C cardioplegia group hearts at similar time point.

Metabolism in reperfused hearts

Consistent with our previous observations [14]-[16], there was a rapid switch in metabolism from anaerobic to aerobic upon reperfusion in both 4°C and 21°C cardioplegia groups, demonstrated by an increase in oxygen consumption and reversal of lactate ratios at peak performance, 90 minutes into reperfusion (Figures 5A and B). Oxygen extraction, lactate production and utilization, reached a steady state in both groups at peak performance that were not significantly different. However, upon reperfusion, 21°C group hearts demonstrated robust synthesis of HEP in the working hearts. In contrast, production was attenuated in 4°C hearts and the HEP continued to decline during course of the experiment. Ratios (post perfusion/pre perfusion) of ATP, CP and total HEP were 1.10, 1.97 and 1.17, respectively in 21°C hearts which were significantly greater (p < 0.01) than ratios of 0.47, 0.32 and 0.38 observed in the 4°C hearts at end of experiment, when post perfusion biopsies were taken for HEP assays.

Figure 5
figure 5

Cardiac metabolism in working hearts . Myocardial O2 Consumption (A) and Lactate Ratio (B) upon perfusion of 4 and 21°C cardioplegia hearts. MVO2 and Lactate ratios were determined from the differences in the respective parameters in the outflow and inflow perfusate samples. Baseline = 60 min after reperfusion, at hemodynamic steady state; 90 min = at peak performance. Each bar represents mean ± SEM of n = 5 for each group.

Functional revival upon reperfusion

Immediate spontaneous activity of both the atria and ventricles was apparent upon commencement of reperfusion in both groups. With increased temperature, force of ventricular contraction peaked at about 37°C after a single cardioversion, which also established the normal electrical activity and electromechanical coupling in sinus rhythm in both groups. While 4 of the 5 hearts in 21°C cardioplegia group reverted to sinus rhythm with a single cardioversion and none requiring further inotropic support, 2 of the 5 hearts in 4°C cardioplegia group required additionally a single dose of epinephrine to maintain optimal function. Interestingly, hearts in both groups remained pliable throughout the experiment and did not show any edema at peak performance as indicated by unaltered thickness of LV and the septum, Table 2. The comparative data between 4 and 21°C cardioplegia groups for cardiac functional parameters acquired by 2D Echo were similar to those observed in vivo (Table 2). Although hearts that received SOMAH cardioplegia at 21°C appeared to have a better recovery, there were no significant differences in the functional parameters of the two groups.

Table 2 Cardiac functional parameters during surgery and at peak performance upon extracorporeal reperfusion in 4°C and 21°C SOMAH cardioplegia group hearts

Discussion

We have designed and evaluated SOMAH, a synergistic extracellular organ storage solution that includes various energy substrates, metabolic modulators, free radical scavengers and anti-oxidants, ammonia chelators and nitric oxide synthase substrates, intra and extracellular H+ chelators and physiological concentration of calcium, components that help prevent edema, ionic imbalance and energy depletion [12]. SOMAH provides a favorable environment and cellular support during ex-vivo storage of hearts, lungs and abdominal organs, and helps attenuate reperfusion injury upon reanimation [13]-[16],[21]. Promising results with organ preservation encouraged us to undertake this study to evaluate SOMAH as a cardioplegia solution.

Recent results from our laboratory show that extracorporeal preservation of hearts for transplant at 21°C (ambient temperatures) in SOMAH is ideal for the highest promotion of synthesis and accumulation of HEP in heart tissue and preservation of ideal function [13]-[16]. Based on these results and on the reported advantages of crystalloid solution [4],[22] and tepid temperatures for cardioplegia [15], the present study was undertaken to evaluate whether using crystalloid SOMAH at 21°C instead of standard temperature of 4°C for cardioplegia could further improve the quality of hearts preserved at ambient temperature in SOMAH, and their eventual reanimation in vitro into optimal function.

Myocardial edema has been reported in hearts arrested at perfusion pressures of cardioplegia as low as 50 mmHg [23]. However, in present and past studies we have consistently used a crystalloid SOMAH cardioplegia infusion pressure of 100 mmHg irrespective of cardioplegia temperature, but edema was not seen in any of the hearts [14]-[16]. SOMAH cardioplegia provides all the advantages of blood cardioplegia, in terms of protection from cardiac edema and provision of substrates for energy metabolism, and also provides clear surgical field. Additionally, provision of physiological concentrations of calcium in SOMAH solution, also prevents the likelihood of myocardial damage due to `calcium paradox' [6],[24]. Furthermore, the disadvantages of blood such as the presence of leukocytes and platelets, culpable in reperfusion injury [25], are also averted. In contrast, the other crystalloid solutions (Celsior and UWS), when used for cardioplegia in our recent studies did not prevent loss of high-energy phosphates in the stored hearts, edema upon reperfusion and potential high K+ mediated calcium overload and stiffness that resulted in non-functioning hearts [14]-[16].

In this study, HEP were conserved in 4°C hearts because of rapid arrest, as a result total concentration of HEP was also greater in these hearts at the end of storage. In contrast, despite K+ concentration (20 mM) being equal in the two groups, the 21°C hearts took longer for total arrest because of absence of the hypothermic component, resulting in depletion of HEP. Both groups synthesized HEP during storage in SOMAH, however, the functional availability of HEP was greater in 21°C hearts than the 4°C hearts at the end of 5 hour (Figure 3). Similarly, upon reperfusion, 21°C hearts continued to synthesize HEP to meet the demands of the working heart, unlike the 4°C hearts. At peak performance the available HEP in 21°C hearts was significantly greater than 4°C hearts, and continued to be so during course of the experiments. In contrast, 4°C hearts were unable to synthesize HEP to keep with the energy demands, thus HEP continued to decrease in the working hearts. These results are in agreement with our previous observations that unlike in hearts preserved in SOMAH at ambient temperatures, exposure to severe hypothermia leads to attenuation of HEP synthesis upon reperfusion in these hearts [13].

Antegrade perfusion was significantly lower in the 4°C heart than in 21°C hearts, and remained diminished, even at higher perfusion pressures until the system temperature stabilized at 37°C (Table 1). It is plausible that sudden shock of encountering 4°C cardioplegia by the normothermic beating heart leads to profound vasoconstriction that does not resolve during storage and only does so upon initiation of reperfusion and raising of temperature to 37°C, and potentially because of active release of vasodilators nitric oxide and prostacyclins [12]. Increased vasodilation, greater coronary vascular patency and a favorable metabolic status provides for rapid nourishment and H+ washout, resulting in robust synthesis of HEP and swift recovery of function in the 21°C hearts. These hearts reverted to sinus rhythm with a single cardioversion and rapidly attained cardiac and hemodynamic parameters approaching in vivo range (Table 2), not requiring any inotropic support. On the other hand, 4°C hearts demonstrated strong contraction only when warmed to 37°C, some of the hearts requiring additional electroversion and/or inotropic intervention, albeit ten times less than that reported in human hearts in vitro[26] to maintain cardiac output.

Release of cardiac enzymes was observed in both the groups upon reperfusion. An important mechanism of release of enzymes from the cardiomyocyte is by cytosol leakage during intracellular vesicular trafficking and incorporation (such as vesicles harboring glucose transporters; GLUT) into cell membrane, by a HEP dependent process, in response to external stimuli like insulin and increased metabolic demands in working hearts [27]. Therefore, release of cellular enzymes can occur even in absence of actual damage to the cardiomyocytes (enzyme paradox). Initial burst of enzyme release in 21°C cardioplegia group upon initiation of reperfusion likely resulted from greater availability of HEP at the end of storage for vesicular transport as the metabolic demands were ramped up with increase in system temperature and cardiac contractility (Figure 3). However, upon reaching metabolic steady state any further release of enzyme was temporally attenuated. In contrast, in the 4°C hearts, the rate of release of enzymes increased with time as more HEP became available for these functions. Even though the present data does not differentiate between progressions of enzyme release and needs further investigation, the fact, that the cardiac functional parameters in both groups were similar and approach the physiological values observed in vivo (Table 2) indicate that the releases of enzymes by the SOMAH hearts is a marker of metabolism rather than tissue injury and hence these hearts would perform well upon transplant.

Certain limitations were inherent to this study. While the present findings indicate a certain advantage of using SOMAH at 21°C for clinical cardioplegia either intraoperatively or during heart procurement for transplantation, in the present preliminary study we have performed only a modest number of experiments in each group and used 2D echocardiography for the functional evaluation of reperfused hearts. While this provided convincing evidence in favor of 21°C cardioplegia, further studies using Pressure-Volume loops acquisition and analysis for precise determination and interpretation of the significant bio-physiological effects of SOMAH on extracorporeal cardiac reperfusion under varying conditions, are required.

Conclusion

Efficient HEP metabolism, decreased rate of enzyme release, and diminished requirement for stimulatory interventions suggest that use of SOMAH for cardioplegia and storage at 21°C optimally protects the heart function and thus may positively influence post operative outcomes upon transplant. Extrapolating ex vivo 5 hour preservation as analogous to cross clamp time, use of SOMAH cardioplegia at ambient temperatures during open heart surgery, where the cross clamp times generally do not exceed 3 hours (average 60-90 minutes); where the hearts are periodically flushed with 500 ml of fresh cardioplegia every 20 to 30 minutes during cross clamp, may significantly improve post surgical outcomes. However, further studies are needed to translate this inferential hypothesis into a clinical reality.

Authors' contributions

SKL and HST designed the experiments and analyzed the data. SKL acquired the 2D Echo data intraoperatively and ex vivo, conducted the experiments and wrote the manuscript. HST performed the heart procurement surgeries, helped in overall conduct of experiments and preparation of the manuscript. PRT assisted in infusion of cardioplegia, set up of ex vivo perfusion apparatus and in conduct of experiments. All authors read and approved the final manuscript.

Additional file

Abbreviations

2D Echo:

2 Dimensional echocardiography

AST:

Aspartate aminotransferase

ATP:

Adenosine tri-phosphate

CK:

Creatine kinase

CP:

Creatine phosphate

cTnI:

Troponin-I

ECG:

Electrocardiograph

HEP:

High energy phosphate

MVO2 :

Myocardial O2 consumption

PA:

Pulmonary artery

PV:

Pulmonary vein

TEE:

Trans-esophageal echocardiography

UWS:

University of Wisconsin Solution

References

  1. Hosenpud JD, Bennett LE, Keck BM, Fiol B, Boucek MM, Novick RJ: The registry of the international society for heart and lung transplantation: fifteenth official report - 1998. J Heart Lung Transplant. 1998, 17: 656-668.

    CAS  PubMed  Google Scholar 

  2. Cohen G, Borger MA, Weisel RD, Rao V: Intraoperative myocardial protection: current trends and future prospects. Ann Thorac Surg. 1999, 68: 1995-2001. 10.1016/S0003-4975(99)01026-7.

    Article  CAS  PubMed  Google Scholar 

  3. Fazel S, Yau TM: Myocardial protection in reoperative coronary artery bypass grafting: toward decreasing morbidity and mortality. J Card Surg. 2004, 19: 291-295. 10.1111/j.0886-0440.2004.4052_11.x.

    Article  PubMed  Google Scholar 

  4. Ovrum E, Tangen G, Tollofsrud S, Oystese R, Ringdal ML, Istad R: Cold blood versus cold crystalloid cardioplegia: a prospective randomized study of 345 aortic valve patients. Eu A Cardio-thorac Surg. 2010, 38: 745-749. 10.1016/j.ejcts.2010.03.052.

    Article  Google Scholar 

  5. Luciani GB, Forni A, Rigatelli G, Chiominto B, Cardaioli P, Mazzucco A, Faggian G: Myocardial protection in heart transplantation using blood cardioplegia: 12-year outcome of a prospective randomized trial. J Heart Lung Transplant. 2011, 30: 29-36. 10.1016/j.healun.2010.08.014.

    Article  PubMed  Google Scholar 

  6. Yamamoto H, Yamamoto F: Myocardial protection in cardiac surgery: a historical review from the beginning to the current topics. Gen Thorac Cardiovasc Surg. 2013, 61: 485-496. 10.1007/s11748-013-0279-4.

    Article  PubMed  Google Scholar 

  7. Fan Y, Zhang AM, Xiao YB, Weng YG, Hetzer R: Warm versus cold cardioplegia for heart surgery: a meta analysis. Eur J Cardio-thorac Surg. 2010, 37: 912-919. 10.1016/j.ejcts.2009.09.030.

    Article  Google Scholar 

  8. Sa MP, Rueda FG, Ferraz PE, Chalegre ST, Vasconcelos FP, Lima RC: Is there any difference between blood and crystalloid cardioplegia for myocardial protection during cardiac surgery? A meta-analysis of 5576 patients from 36 randomized trials. Eu A Cardio-thorac Surg. 2012, 27 (6): 535-546.

    CAS  Google Scholar 

  9. White CW, Ali A, Hasanally D, Xiang B, Li Y, Mundt P, Lytwyn M, Colah S, Klein J, Ravandi A, Arora RC, Lee TW, Hryshko L, Large S, Tian G, Freed DH: A cardioprotective preservation strategy employing ex vivo heart perfusion facilitates successful transplant of donor hearts after cardiocirculatory death. J Heart Lung Transplant. 2013, 32: 734-743. 10.1016/j.healun.2013.04.016.

    Article  PubMed  Google Scholar 

  10. Belzer FO, Southard JH: Principles of solid-organ preservation by cold storage. Transplantation. 1988, 45 (4): 673-676. 10.1097/00007890-198804000-00001.

    Article  CAS  PubMed  Google Scholar 

  11. Stefanovich P, Ezzel RM, Sheehan SJ, Tompkins RG, Yarmush ML, Toner M: Effects of hypothermia on the function, membrane integrity, and cytoskeletal structure of hepatocytes. Cryobiology. 1995, 32: 389-403. 10.1006/cryo.1995.1039.

    Article  CAS  PubMed  Google Scholar 

  12. Thatte HS, Rousou L, Hussaini BE, Lu XG, Treanor PR, Khuri SF: Development and evaluation of a novel solution, Somah, for the procurement and preservation of beating and non-beating donor hearts for transplantation. Circulation. 2009, 120: 1704-1713. 10.1161/CIRCULATIONAHA.108.808907.

    Article  PubMed  Google Scholar 

  13. Lowalekar SK, Lu XG, Thatte HS: Further evaluation of somah: long-term preservation, temperature effect and prevention of ischemia-reperfusion injury in rat hearts harvested after cardiocirculatory death. Transplant Proc. 2013, 45 (9): 3192-3197. 10.1016/j.transproceed.2013.06.006.

    Article  CAS  PubMed  Google Scholar 

  14. Lowalekar SK, Cao H, Lu XG, Treanor R, Thatte HS: Subnormothermic preservation in SOMAH: a novel approach for enhanced functional resuscitation of donor hearts for transplant. Am J Transplant. 2014

    Google Scholar 

  15. Lowalekar SK, Cao H, Lu XG, Treanor PR, Thatte HS: Hearts preserved in Somah at sub-normothermia demonstrate rapid functional restoration and are less likely to develop heart failure upon transplantation. Abstract. J Heart Lung Transplant. 2014, 33 (4): S176-10.1016/j.healun.2014.01.475.

    Article  Google Scholar 

  16. Lowalekar SK, Cao H, Lu XG, Treanor PR, Thatte HS: Sub-normothermic preservation of donor hearts for transplantation using a novel solution, SOMAH: a comparative pre-clinical study. J Heart Lung Transplant. 2014, 33 (9): 963-970. 10.1016/j.healun.2014.05.006.

    Article  PubMed  Google Scholar 

  17. Fukuhiro Y, Wowk M, Ou R, Rosenfeldt F, Pepe S: Cardioplegic strategies for calcium control: low Ca2+, high Mg2+, citrate, or Na+/H + exchange inhibitor HOE-642. Circulation. 2000, 102 (19-3): III319-III325.

    CAS  PubMed  Google Scholar 

  18. Osaki S, Ishino K, Kotani Y, Honjo O, Suezawa T, Kanki K, Sano S: Resuscitation of non-beating donor hearts using continuous myocardial perfusion: the importance of controlled initial reperfusion. Ann Thorac Surg. 2006, 81: 2167-2171. 10.1016/j.athoracsur.2006.01.066.

    Article  PubMed  Google Scholar 

  19. Bessho M, Ohsuzu F, Yanagida S, Sakata N, Aosaki N, Tajima T, Nakamura H: Differential extractability of creatine phosphate and ATP from cardiac muscle with ethanol and perchloric acid solution. Anal Biochem. 1991, 192: 117-124. 10.1016/0003-2697(91)90195-Y.

    Article  CAS  PubMed  Google Scholar 

  20. Klabunde R: Cardiac function. Cardiovascular Physiology Concepts. 2011, Lippincott Williams & Wilkins, Baltimore, MD USA, 84-88.

    Google Scholar 

  21. Louis AV, Hemphill C, Schipper D, Qu N, Stavoe K, Penick K, Thatte HS, Khalpey Z: Extended preservation of lungs at subnormothermia with a novel organ storage solution "SOMAH": salvage, reconditioning and functional evaluation. Abstract. J Heart Lung Transplant. 2014, 33 (4): S71-10.1016/j.healun.2014.01.225.

    Article  Google Scholar 

  22. Charniot JC, Bonnefont-Rousselot D, Albertini JP, Dever S, Vignat N, Nataf P, Pavie A, Monsuea JJ, Delattre J, Artigou JY: Oxidative stress implication after prolonged storage donor heart with blood versus crystalloid cardioplegia and reperfusion versus static storage. J Sur Res. 2009, 160: 308-314. 10.1016/j.jss.2009.03.023.

    Article  Google Scholar 

  23. Mehlhorn U, Geissler HJ, Laine GA, Allen SJ: Myocardial fluid balance. Eur J Cardiothorac Surg. 2001, 20: 1220-1230. 10.1016/S1010-7940(01)01031-4.

    Article  CAS  PubMed  Google Scholar 

  24. Piper HM: The calcium paradox revisited: an artifact of great heuristic value. Cardiovasc Res. 2000, 45: 123-127. 10.1016/S0008-6363(99)00304-1.

    Article  CAS  PubMed  Google Scholar 

  25. Han S, Huang W, Liu Y, Pan S, Feng Z, Li S: Does leukocyte-depleted blood cardioplegia reduce myocardial reperfusion injury in cardiac surgery? A systematic review and meta-analysis. Perfusion. 2013, 28 (6): 474-483. 10.1177/0267659113492837.

    Article  CAS  PubMed  Google Scholar 

  26. Hill AJ, Laske TG, Coles JA, Sigg DC, Skadsberg ND, Vincent SA, Soule CL, Gallagher BA, Iaizzo PA: In vitro studies in human hearts. Am Thorac Surg. 2005, 79: 168-177. 10.1016/j.athoracsur.2004.06.080.

    Article  Google Scholar 

  27. Ferrera R, Benhabbouche S, Bopassa JC, Li B: One hour reperfusion is enough to assess function and infarct size with TTC staining in Langendorff rat model. Cardiovasc Drugs Ther. 2009, 23: 327-331. 10.1007/s10557-009-6176-5.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Peter Hirsch, MS, for his assistance during pre and post surgery in the OR. We gratefully acknowledge the assistance of Diane Ghera, BS, and her staff at the VABHS animal care facility. We thank Aditi Thatte for her encouragement and support. We greatly appreciate Susan Greely, Louise Connelly, Michael Charpak and Dr. Frances Achee for their continuing administrative support.

Support

This work was supported by VA Merit Review grant (Dr. Thatte), Department of Veterans Affairs, Office of Research and Development, Washington DC, and an unrestricted gift from Somahlution (Jupiter, Fl) to Boston VA Research Institute for research (Dr. Thatte).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hemant S Thatte.

Additional information

Competing interests

The authors declare that they have no competing interests.

Electronic supplementary material

Authors’ original submitted files for images

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions